General

SettingDefaultMeaning
Design CodeB31.3ASME B31.3 (Process), ASME B31.1 (Power) or AS 4041 — selects the stress equations and factors. (spec-overridable)
Unit SystemMetricDisplay units only; the model stores metric internally.
Internal Pressure (MPa/psi)0Global design pressure. (spec-overridable)
Fluid Density (kg/m³)1000Contents weight; 0 for gas. (spec-overridable)
Temperatures — Install / Design Max / Design Min (°C)21 / 80 / −10Thermal range. OPE uses the worst single excursion from install; EXP uses the full displacement-stress range (hot and cold when T_min ≠ install). (spec-overridable)
Vertical AxisZWhich global axis is "up" — affects gravity, wind elevation and support conventions. Set before modelling.
Ground Elevation0Elevation of the ground surface on the vertical axis. Burial depth of every buried element is computed automatically as (Ground Elevation − pipe centreline elevation), so depth varies along risers; buried pipe at or above this level gets no soil restraint (a warning is issued).

Code Compliance Options

SettingDefaultMeaning
Equivalent Full Cycles N7000Sets the stress-range factor f = 6·N⁻⁰·² ≤ 1.0 in SA. ≤ 7000 cycles → f = 1.0. (spec-overridable)
Use liberal expansion allowable (Eq 1b)onSA = f[1.25(Sc + Sh) − SL] — credits unused sustained margin (common industry default). Off = basic f(1.25·Sc + 0.25·Sh).
Include pressure elongation (Bourdon effects)offAdds the closed-pipe axial pressure strain (σL − ν·σH)/E (including end-cap thrust at blind ends) to pressure-bearing cases. Off is the industry default.
Weld Joint Factor E1.0Quality factor in the hoop-pressure wall check t = PD/[2(SE + PY)].
Y Coefficient0.4B31.3 Table 304.1.1 coefficient in the same check.
Occasional k (B31.1 only)1.20Occasional-stress factor (1.15 / 1.20 / 1.33).

Report Header

Company, Project No., Revision, Prepared By, Checked By, and a logo upload — all printed on the PDF report. Saved with the project.

Wind Load Settings (Pro)

  • Code: ASCE 7 or AS 1170.2.
  • ASCE 7: Basic wind speed V, exposure category B/C/D, wind angle.
  • AS 1170.2: Regional speed V_R, terrain category 1–4, direction multiplier M_d, topographic multiplier M_t, angle.
  • A non-zero wind speed makes OCC-WIND available and included in Run All Cases.

Seismic Load Settings (Pro)

  • Code: GENERIC (horizontal g-factor + direction X/Y/Z) or AS 1170.4 (kp, hazard factor Z, site class Ae–Ee, ac, rc).
  • Configured seismic input enables OCC-SEIS and includes it in Run All Cases. Valve actuator CoG offsets generate eccentric torsion; snubbers lock during the event.

Tools in this tab

  • Auto-Size Spring Hangers — two-pass MSS SP-58 sizing writing rate + preload into auto-size springs.
  • Run Modal Analysis — natural frequencies + mass participation, viewable as animated mode shapes.